• OEM/ODM Service Submersible Water Pump with Support 12V 24V PWM Speed Regulation
  • OEM/ODM Service Submersible Water Pump with Support 12V 24V PWM Speed Regulation
  • OEM/ODM Service Submersible Water Pump with Support 12V 24V PWM Speed Regulation
  • OEM/ODM Service Submersible Water Pump with Support 12V 24V PWM Speed Regulation

OEM/ODM Service Submersible Water Pump with Support 12V 24V PWM Speed Regulation

Max.Head: 4m
Max.Capacity: 32L/Min
Driving Type: Magnetic
Material: ABS,Pes/Sps/PPS/PA66+30%GF (Optional)
Structure: Single-stage Pump
Assembly: Liquid Pumps
Samples:
US$ 35/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
DC50C
Power
Electric
Start Up
Electric Pump
Type
Positive-Displacement Pump
Application
Submersible Pump
Industry
Air Conditioning Pump
Media
Water,Refrigerating Fulid
Performance
Automatic Pump
Theory
Centrifugal Pump
Protection Level
IP68
Service Life
30,000hrs
Transport Package
Standard Export Packing or OEM Packing
Trademark
ZKSJ
Origin
China
HS Code
8413709190
Production Capacity
100, 000 PCS/Month

Product Description

OEM/ODM Service Submersible Water Pump with Support 12V 24V PWM Speed Regulation

Specifications
NO. Item Specs
1 Dimension and weight 106mmx97.5mmx71.5mm;480g
2 External diameter of outlet 1/2" thread(M20)
3 External diameter of inlet 1/2" thread(M20)
4 Driving mechanism Brush-less, magnetic isolated design
5 Material of pump shell ABS,PES/SPS/PPS/PA66+30%GF (Optional)
6 Condition of use Can continuously work, submersible or land use (not self-priming)
7 Suitable medium Water, oil, or normal acid/ alkaline liquids
(Pre-test needed for special liquid)
8 Max working temperature 60ºC(for T sub-series) or 100ºC(for S/A sub-series)
9 Power consumption 2.5W~48W(for T sub-series) or 2.5W~86.4W(for S/A sub-series)
10 Rated voltage 12Vdc or 24Vdc
11 Working voltage range 5Vdc ~ 14Vdc or 5Vdc ~ 26Vdc
12 Max load current 2.0A (for T sub-series) or 4.5A(for S/A sub-series)
13 Max horizontal flow rate 32L/MIN(for T sub-series) or 40L/MIN(for S/A sub-series)
14 Max static lift 4M(for T sub-series) or 8M(for S/A sub-series)                                  
15 Noise class <40dB
16 Waterproof class IP68(suitable for submersible installation)
17 Life span >30,000hrsIP68(suitable for submersible installation)
18 Power supply Suitable solar panel, batteries, adapter or other power source
19 Protection function Dry-run protection, lock protection(customized function)
20 Power regulation function Speed adjustable by PWM signal, 0~5V analog signal or potentiometer (functions are optional for customization)
22           Feature
  • small size with high efficiency,maintenance-free
  • Use ceramics shaft and carbon fiber sleeve
  • Completely water proof (IP68)
  • Brush-less dc control without pollution, long life span
  • OEM and ODM service accept
  • Offer Pump related control system design




Pump Structure

OEM/ODM Service Submersible Water Pump with Support 12V 24V PWM Speed Regulation
Electrical parameters 
(only for reference,parameters can be customized for specific requirements)
Model No. Voltage Max load current Max static lift Max flow rate Power consumption
  V(dc) A M L/H w
DC50C-1230T 12 2.0 3.0 1680 24
DC50C-1230S
DC50C-1230A
DC50C-1260S 12 4.5 6.0 2100 54
DC50C-1260A
DC50C-2440T 24 2.0 4.0 1920 48
DC50C-2440S
DC50C-2440A
DC50C-2480S 24 3.60 8.0 2400 86.4
DC50C-2480A
     NOTE
  •  Information including continuous working time, working temperature and medium is required to be pre-confirmed with professionals; pump cannot work with high temperature or corrosive fluids.
  •  When pump is connected into circulation system, load current will be reduced to 70~85% of Max working current (opening outlet current).
  •  The head means the Max vertical lifting height of water,the flow is 0L/MIN@max head.
  •  The max flow rate means flow rate with no lifting height(according to the curve bellow)


Difference between 2phase & 3phase brushless DC pump
   2phase 
(T sub-series)
 Hall sensor driving, circuit board should be placed inside pump body
   3phase
(S/A sub-series)
  • NOTE that 3phase dc is completely different with 3phase AC; 3phase DC means 3 pairs of magnetic polarity & sensor-less, power supply  the same with common DC pump
  • Intelligent program-driving, sensor-less, circuit outside of pump body (main factor that pump can be high-temperature resistant)
  • Speed adjustable by PWM, 0~5V signal or potentiometer(optional)
  • Lock protection,reverse-connected protection, over-vol.&over-current protection,
  • Soft start, no current impact, can be contact directly with solar panel
OEM/ODM Service Submersible Water Pump with Support 12V 24V PWM Speed Regulation
OEM/ODM Service Submersible Water Pump with Support 12V 24V PWM Speed Regulation
OEM/ODM Service Submersible Water Pump with Support 12V 24V PWM Speed Regulation
OEM/ODM Service Submersible Water Pump with Support 12V 24V PWM Speed Regulation



Dimensions of pump

OEM/ODM Service Submersible Water Pump with Support 12V 24V PWM Speed Regulation




production test

OEM/ODM Service Submersible Water Pump with Support 12V 24V PWM Speed Regulation
OEM/ODM Service Submersible Water Pump with Support 12V 24V PWM Speed Regulation


Exploded diagram of the product 
OEM/ODM Service Submersible Water Pump with Support 12V 24V PWM Speed Regulation
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 9000, IATF16949